Wheel Loader Exhaust Gas Purifier

Purification rate 90%
Filter life Washable metal cores
Regeneration 1-minute water wash
Customisation Built to engine model

Product Introduction

A 3-tonne and a 12-tonne loader differ fourfold in exhaust volume. We size this unit by displacement and annual running hours rather than by tonnage; the metal element is washed again and again, so over the years a machine consumes seals, not cores.

Detailed Overview

01 Product Introduction

The Wheel Loader exhaust gas purifier is a new-generation black smoke purifier developed by AIFILTECH using its own patented design. Its core is a TPS water-washable regenerative metal filter element (metal DPF, patent No. ZL 2018 1 0598975.7) made from special high-temperature-resistant, corrosion-resistant metal media through more than 30 processes. Particulate filtration efficiency reaches over 90%, regeneration by water washing takes about one minute, and the unit produces no secondary pollutants, has a long service life, withstands rough handling and keeps running costs low. It is suitable for wheel loaders in aggregate yards, batching plants, mines and coal yards. Nearly 5,000 sets are in service across China.

Configured for the high displacement and smoke density of wheel loaders, core count and flow area are matched to engine displacement, and the all-metal structure withstands sustained heat and vibration under heavy-duty cycles.

Working conditions: Wheel loaders work under heavy load in dusty environments with high smoke opacity and sharply varying duty cycles, calling for high soot capacity and strong thermal-shock resistance.

Wheel loader purifier 3D diagram

02 Working Principle

Exhaust gas emitted by diesel engines enters the air inlet of the AIFILTECH exhaust filtration system. The gas, laden with carbon particles, passes from the outside to the inside through the TPS filter element, where the particles are captured by the element wall and the clean gas is discharged into the atmosphere from the air outlet.

Hot exhaust enters the housing and passes through the outer surface of the core into the element body; black smoke and carbon particles are blocked on the outer surface, and the cleaned gas is collected through the core outlet and discharged from the exhaust port.

As the engine runs continuously, carbon particles accumulate on the outer surface of the core and system back pressure gradually rises. Once back pressure reaches the set value, the machine can be stopped, the clamp removed, the core pulled out and rinsed clean under a tap, then reinstalled into the housing and the clamp retightened for further use — a cycle that repeats. Initial back pressure is as low as 1 kPa, so normal engine operation is barely affected. The specially designed particulate trap offers high soot-holding capacity and long service intervals with low maintenance. When back pressure reaches the preset value (generally 25 kPa), an alarm can be set to remind the operator to regenerate the core.

Exhaust purifier structure diagram (air inlet, TPS filter element, supporting plate, mounting bracket, exhaust outlet, back pressure gauge)

03 Product Advantages

  • Particulate filtration efficiency over 90%, with a measured light absorption coefficient below 0.5 m⁻¹;
  • Easy regeneration: 1-minute water-washing regeneration, reusable without damage;
  • Quick to fit: clamp-on design, removed and refitted in about 30 seconds;
  • No secondary pollutants;
  • Low total cost of ownership: the retrofit is straightforward and maintenance is simple;
  • Core count and flow area are matched to loader displacement, and the all-metal structure withstands sustained heat and vibration under heavy load.
Particulate filtration efficiency curveAdvantages overview: high filtration efficiency, washable regeneration, easy installation, zero secondary pollution

04 Certifications & Application Cases

The unit was tested by an independent laboratory holding CMA and CNAS accreditation; the measured light absorption coefficient was below 0.5 m⁻¹.

Since the AIFILTECH water-washable regenerative metal purifier was successfully developed, the core product has passed nearly 5,000 installations in the after-treatment market and has become a main equipment supplier for non-road diesel retrofit programmes in China. The company joined the non-road retrofit programme in Nanjing back in 2018 and has since completed nearly 1,000 installations there, with users now spread across the country. These units run daily at Beijing Capital, Guangzhou Baiyun, Xiamen, Nanchang and Nanning airports, and at port terminals, in corporate wheel loader fleets and on construction sites.

Typical applications: wheel loaders in aggregate yards, batching plants, mines and coal yards. The model is already in volume service in these applications, with selection calculation, installation guidance and commissioning support provided.

Wheel loader retrofit at jobsite

Sizing & selection Q&A

Which rating fits my machine?

Same displacement usually shares one unit across engine brands, so the plate photo is enough to match it.

What smoke opacity can it hold?

The test conditions sit in the datasheet. What counts after installation is the re-test reading, not the catalogue number.

Do I ship the core back for regeneration?

No return shipment. Pull the unit, rinse the core, clamp it back — the substrate is reused, not consumed.

Can it be fitted before an inspection date?

Direct fit, no pipe cutting, and a single unit goes on inside an inspection window. The clamp design also comes off fast.

How do I match a foreign test method?

Send the local test method and limit value; the model and the acceptance evidence are matched to that method rather than to a generic claim.

Applications

Diesel generator sets Construction machinery Wheel loaders Marine auxiliary engines Mining equipment Engine test benches Emergency power trucks Tunnel construction Airports Port terminals Construction sites Municipal roads
Need the full technical data? Download the PDF datasheet for complete technical data, key figures and selection guidance.
Download Datasheet

All data above are obtained under specific test conditions; the actual solution must be engineered to site conditions. AIFILTECH provides custom design and sizing based on actual gas volume, temperature, dust characteristics and emission limits.