Titanium Felt, Nickel Felt and Porous Titanium Plate for Water Electrolysis: Selection, Contact Resistance and Life, 16 Questions
These 16 questions cover the topics buyers raise most often about titanium felt, nickel felt and porous titanium plate for water electrolysis. Answers are based on AIFILTECH product documentation, maintenance guides and field experience, and sit alongside the main FAQ hub and the companion guides in this series. Technical values are governed by the model test report and the signed technical agreement.
All 16 questions at a glance
- 1. Which porous materials suit ALK, PEM, AEM and SOEC electrolysers?
- 2. Where in the electrolyser are titanium felt, nickel felt, composite nickel felt, nickel mesh and porous titanium plate used?
- 3. How do porosity, thickness and fibre diameter affect contact resistance and mass transport?
- 4. Is the quoted contact resistance a raw value or a value measured at a specific pressure and surface treatment?
- 5. What are the test pressure, method and sample count for contact resistance?
- 6. What are material purity, areal density, thickness and dimensional tolerances?
- 7. How is batch-to-batch consistency of porosity and resistance ensured?
- 8. Do titanium or nickel felts need a coating, and what does it do?
- 9. How are loading, uniformity and adhesion of Pt/Ir coatings tested?
- 10. Can a comparison test of uncoated and coated samples be provided?
- 11. What corrosion data exist for alkaline, acidic and long-term electrochemical conditions?
- 12. How are compression recovery and thickness change evaluated after stack assembly?
- 13. Can material be cut, stamped, welded or laminated to an electrolyser drawing?
- 14. Can small samples and test reports be provided for R&D validation?
- 15. Can performance and dimensions be kept consistent from sample validation to volume supply?
- 16. How is material life evaluated, not just initial performance?
Electrolysis routes and material selection
1. Which porous materials suit ALK, PEM, AEM and SOEC electrolysers?
ALK uses 20%–30% KOH; electrodes and current collectors are mostly nickel mesh, nickel felt, nickel foam or Raney nickel, and titanium is essentially absent from the stack. The PEM anode is a perfluorosulfonic strong-acid, oxygen-evolving environment at about 1.4–2.0 V vs RHE, where nickel and stainless steel dissolve rapidly, so Grade 1/2 commercially pure titanium felt or sintered porous titanium plate is required as the PTL, usually with Pt/Ir protective coatings to suppress TiO2 passivation; the cathode generally uses carbon paper or carbon cloth GDL and is not selected as the anode. AEM uses an alkaline solid membrane with nickel felt, nickel mesh or stainless steel; some designs choose titanium felt on the anode for corrosion margin. SOEC operates at 700–850 °C with a Ni-YSZ ceramic hydrogen electrode and a perovskite oxygen electrode, and uses almost no low-temperature metal PTL inside the stack, so AIFILTECH titanium felt, nickel felt, nickel mesh and porous titanium plate are generally not applicable. These are typical public-route selections; the final choice follows stack chemistry, potential window and structural validation.
2. Where in the electrolyser are titanium felt, nickel felt, composite nickel felt, nickel mesh and porous titanium plate used?
They can serve as porous transport layers, electrode supports or part of the current-collecting structure; whether they sit at the anode, cathode or in a composite electrode layer depends on the electrolysis route and stack design. Fibre felt is more compressible, mesh is more regular, and powder-sintered titanium plate is more rigid. Position cannot be judged from the material name alone; consider the catalyst, membrane and flow-field interfaces.
3. How do porosity, thickness and fibre diameter affect contact resistance and mass transport?
Higher porosity and connected pores help water and gas transport, but too much can reduce effective contact points. Thinner material shortens transport and conduction paths but may lower mechanical stability. Fibre diameter and surface structure affect contact, pore throats and catalyst-layer support. These interact and must be optimised at a specified compression rate, current density and flow field; there is no universal highest-porosity-is-best rule.
4. Is the quoted contact resistance a raw value or a value measured at a specific pressure and surface treatment?
Contact resistance must state test pressure, counter-material and surface, coating, sample orientation and whether it is compressed, because pressure changes real contact area and oxidation or coating changes interfacial resistance. The ≤5 mΩ·cm² figure on the AIFILTECH product page is a reference value; test pressure, counter-face, coating state, sample count and original curves must be confirmed in the model datasheet or test report before comparison with other makers. Until then it is not a batch guarantee value.
5. What are the test pressure, method and sample count for contact resistance?
Report area-specific contact resistance across a pressure gradient rather than a single point. Record the fixture, counter-plate material and roughness, coated face, compression rate, current method, environment, sample count and scatter. Pressure should cover the actual stack assembly range, with data before and after cyclic compression and after ageing where needed.
6. What are material purity, areal density, thickness and dimensional tolerances?
AIFILTECH titanium felt has titanium purity ≥99.5%, thickness 0.2–1.0 mm (customisable), porosity 50%–75% (customisable / graded), pore size 18–50 μm (optional graded pore structure), area resistance ≤5 mΩ·cm² and Pt coating 0.2–0.5 μm. Nickel felt is a different product with porosity 50%–80% and pore size 18–60 μm; porous titanium plate has pore size 5–100 μm, porosity 25%–50% and thickness 0.5–10 mm. These are typical product-page values; see the AIFILTECH product catalogue for details, and the batch guarantee values in the signed technical agreement.
Coatings, processing, samples and durability
7. How is batch-to-batch consistency of porosity and resistance ensured?
Control fibre raw material, felt laying, sintering, rolling, surface treatment and slitting, and manage areal density, thickness, porosity, permeability and contact resistance with batch statistics.
8. Do titanium or nickel felts need a coating, and what does it do?
It depends on the electrolysis side. The PEM anode is a perfluorosulfonic strong-acid, oxygen-rich environment at 50–80 °C with an anode potential of about 1.4–2.0 V vs RHE; an insulating TiO2 passive film forms on titanium and raises interfacial contact resistance (ICR), so industrial designs normally apply Pt, Ir or Au precious-metal protective coatings to the titanium PTL, with lower-precious-metal options such as TiOx/TiHx conductive layers or Ta interlayers. The coating itself can dissolve or peel under high potential, start-stop and load changes, so adhesion, loading and aged ICR must be verified. In ALK/AEM, nickel felt and nickel mesh serve mainly as electrode substrates or catalyst-layer supports; whether a catalytic or protective layer is needed follows electrode design, and precious-metal coatings are generally not required. Hydrogen embrittlement of titanium on the cathode hydrogen-evolution side also needs assessment. The coating scheme is finally confirmed by single-cell polarisation and durability data; stack life is not promised from this alone.
9. How are loading, uniformity and adhesion of Pt/Ir coatings tested?
Report coating thickness and areal loading separately; they are not interchangeable. Use suitable microscopy and composition methods to check coverage and uniformity, weighing or analysis to quantify loading, and standardised adhesion and electrochemical durability tests for bonding; coverage inside the porous fibre structure also matters.
10. Can a comparison test of uncoated and coated samples be provided?
If the customer requires it, AIFILTECH can supply matched uncoated and coated samples from the same substrate, dimensions and compression conditions against a sample order. Sample and test costs, report scope and ageing conditions are agreed in the order; samples and testing are charged as quoted.
11. What corrosion data exist for alkaline, acidic and long-term electrochemical conditions?
Assess corrosion current, metal dissolution, mass, morphology and resistance change against the specific solution composition, concentration, temperature, potential or current density, time and sample state. Static immersion cannot replace long-term electrochemical operation, and a short stack test cannot be extrapolated directly to life; combine material analysis with single-cell durability testing.
12. How are compression recovery and thickness change evaluated after stack assembly?
Measure free thickness, target compression rate, pressure/thickness curve, unloading recovery and permanent set after cycling under the actual gasket and flow-field constraints, and observe contact uniformity and local stress on the membrane. A single compression rate does not suit every PTL; fibre felt and powder-sintered plate behave differently.
13. Can material be cut, stamped, welded or laminated to an electrolyser drawing?
Cutting, stamping and some lamination can be reviewed against the drawing, checking burrs, edge deformation, surface contamination, dimensional tolerance and the orientation of two-layer media. Public PTL literature suggests mechanical cutting within tolerance or laser cutting with fire precautions; welding and lamination require additional verification of contact and corrosion performance.
14. Can small samples and test reports be provided for R&D validation?
R&D cooperation starts with a sample order: the customer purchases small samples to an agreed specification, and AIFILTECH supplies batch data corresponding to the production process (material, thickness, areal density, porosity, contact resistance, surface treatment and dimensions). Sample scope, cost, confidentiality and subsequent volume pricing are set out in the sample order; samples and testing are charged as quoted. Once validation is satisfactory, volume supply is discussed, with first-article approval and batch sampling before production. Sample test conditions should match the customer stack, with retained control samples from the same batch where needed.
15. Can performance and dimensions be kept consistent from sample validation to volume supply?
AIFILTECH freezes material grade, structure, thickness, porosity, coating and processing at the sample stage, then performs first-article approval and agreed batch sampling before production. Any change in production equipment or process is reassessed for equivalence.
16. How is material life evaluated, not just initial performance?
Track voltage, high-frequency or contact resistance, metal dissolution, coating integrity, pore structure and mechanical deformation over time, covering start-stop, load changes and the actual water or alkaline electrolyte. Report test duration, failure criteria and degradation rate; do not promise years of stack life from short-term stability alone.
Related FAQ guides and further reading
- Ceramic Fibre Filter Tubes and All-in-One Catalytic Tubes: Selection, Temperature Windows and DeNOx, 19 Questions
- Metal Filter Bags, Cartridges and Sintered Metal Media: Materials, Accuracy and Cleaning, 31 Questions
- High-Temperature Dust Collection Systems and EPC: Design, Explosion Protection and Acceptance, 32 Questions
- Testing, Certification, Pricing, Lead Time and Export Purchasing: 26 Questions
- Installation, Training, Warranty, After-Sales and Maintenance: 30 Questions
- Diesel Exhaust Purifier FAQ: 36 Questions
- Diesel Generator Exhaust Purifier FAQ: 22 Questions
- Forklift, Construction, Farm and Airport Vehicle DPF FAQ: 15 Questions
- DOC+DPF+SCR+ASC and Other Technology Routes FAQ: 18 Questions
Need a model confirmed for your duty, or the technical documentation? Send the gas or engine parameters, target emissions and site conditions, and we will check the applicable model and acceptance basis against the data.
Bruce Wen · +86 188 1936 6808 (mobile / WhatsApp / WeChat) · bruce.wen@aifiltech.com